MP-6(3) Media Sanitization | Nondestructive Techniques
Apply nondestructive sanitization techniques to portable storage devices prior to connecting such devices to the system under the following circumstances: organization-defined circumstances requiring sanitization of portable storage devices.
Source: NIST SP 800-53 Rev 5, MP-6(3). The statement above is our statement of the clause, read from the published text and cited so you can check it against the official text, not the instrument verbatim. Open NIST SP 800-53 Rev 5 in the compliance library.
Base controls and their enhancements. Which apply follows the baseline you are assessed against (for example FedRAMP Moderate or High, or the low, moderate and high baselines of SP 800-53B). Text in square brackets is a parameter your organisation sets.
These are the artefacts auditors commonly ask for on this requirement, our guidance rather than text from the standard. Your assessor decides what is sufficient in your context, and asks for samples across the period when a report covers one.
system holds itEvidence a system already holds
- List of circumstances requiring sanitization of portable storage devices · Endpoint management (MDM / EDR)
periodic reviewEvidence produced at each review
- Media sanitization records · Data governance / DLP tooling
- Audit records · Data governance / DLP tooling
- Test of Organizational processes for media sanitization of portable storage devices; mechanisms supporting and/or implementing media sanitization · Endpoint management (MDM / EDR)
governing documentDocuments that govern the control
- System media protection policy · Policy repository / GRC workspace
- Procedures addressing media sanitization and disposal · Policy repository / GRC workspace
- Information on portable storage devices for the system · Policy repository / GRC workspace
- System security plan · Policy repository / GRC workspace
First move
Common gaps auditors find
- Circumstances requiring nondestructive sanitization of portable storage devices before connection are not defined
- Portable devices from external sources are connected to the system without prior nondestructive sanitization being applied