MP-6(2) Media Sanitization | Equipment Testing
Test sanitization equipment and procedures organization-defined frequency to ensure that the intended sanitization is being achieved.
Source: NIST SP 800-53 Rev 5, MP-6(2). The statement above is our statement of the clause, read from the published text and cited so you can check it against the official text, not the instrument verbatim. Open NIST SP 800-53 Rev 5 in the compliance library.
Base controls and their enhancements. Which apply follows the baseline you are assessed against (for example FedRAMP Moderate or High, or the low, moderate and high baselines of SP 800-53B). Text in square brackets is a parameter your organisation sets.
These are the artefacts auditors commonly ask for on this requirement, our guidance rather than text from the standard. Your assessor decides what is sufficient in your context, and asks for samples across the period when a report covers one.
system holds itEvidence a system already holds
none for this control
periodic reviewEvidence produced at each review
- Results of media sanitization equipment and procedures testing · Data governance / DLP tooling
- System audit records · Data governance / DLP tooling
- Test of Organizational processes for media sanitization; automated mechanisms supporting and/or implementing media sanitization; automated mechanisms supporting and/or implementing media sanitization procedures; sanitization equipment · Data governance / DLP tooling
governing documentDocuments that govern the control
- System media protection policy · Policy repository / GRC workspace
- Procedures addressing media sanitization and disposal · Policy repository / GRC workspace
- Procedures addressing testing of media sanitization equipment · Policy repository / GRC workspace
- Records retention and disposition policy · Policy repository / GRC workspace
- Records retention and disposition procedures · Policy repository / GRC workspace
- System security plan · Policy repository / GRC workspace
- Privacy plan · Policy repository / GRC workspace
First move
Common gaps auditors find
- Sanitization equipment such as degaussers and shredders has no test records showing the intended sanitization is achieved
- The organization-defined frequency for testing sanitization equipment and procedures was never set or is not followed