SI-7(5) Software, Firmware, and Information Integrity | Automated Response to Integrity Violations
Automatically Selection (one or more): shut the system down; restart the system; implement [organization-defined controls] when integrity violations are discovered.
Source: NIST SP 800-53 Rev 5, SI-7(5). The statement above is our statement of the clause, read from the published text and cited so you can check it against the official text, not the instrument verbatim. Open NIST SP 800-53 Rev 5 in the compliance library.
Base controls and their enhancements. Which apply follows the baseline you are assessed against (for example FedRAMP Moderate or High, or the low, moderate and high baselines of SP 800-53B). Text in square brackets is a parameter your organisation sets.
These are the artefacts auditors commonly ask for on this requirement, our guidance rather than text from the standard. Your assessor decides what is sufficient in your context, and asks for samples across the period when a report covers one.
system holds itEvidence a system already holds
- Records of integrity scans · Vulnerability scanner / patch tooling
periodic reviewEvidence produced at each review
- Records of integrity checks and responses to integrity violations · Document repository
- Audit records · Policy repository / GRC workspace
- Test of Software, firmware, and information integrity verification tools; mechanisms providing an automated response to integrity violations; mechanisms supporting and/or implementing security safeguards to be implemented when integrity violations are discovered · Document repository
governing documentDocuments that govern the control
- System and information integrity policy · Policy repository / GRC workspace
- System and information integrity procedures · Policy repository / GRC workspace
- Procedures addressing software, firmware, and information integrity · Policy repository / GRC workspace
- System design documentation · Document repository
- System configuration settings and associated documentation · Policy repository / GRC workspace
- Integrity verification tools and associated documentation · Document repository
First move
Common gaps auditors find
- Systems keep running after integrity violations because no automatic shutdown, restart or defined control is configured
- Automated response to integrity violations was disabled after a false alarm and never re-enabled or replaced
Do this for your whole sheet
Paste the rows you run your controls from and get this mapping for every control at once, with the periodic-review ones flagged and a first move per row. No account for the first run.
Build my evidence sheetSI-7(3) Software, Firmware, and Information Integrity | Centrally Managed Integrity Tools · SI-7(6) Software, Firmware, and Information Integrity | Cryptographic Protection