SI-7(2) Software, Firmware, and Information Integrity | Automated Notifications of Integrity Violations
Employ automated tools that provide notification to organization-defined personnel or roles upon discovering discrepancies during integrity verification.
Source: NIST SP 800-53 Rev 5, SI-7(2). The statement above is our statement of the clause, read from the published text and cited so you can check it against the official text, not the instrument verbatim. Open NIST SP 800-53 Rev 5 in the compliance library.
Base controls and their enhancements. Which apply follows the baseline you are assessed against (for example FedRAMP Moderate or High, or the low, moderate and high baselines of SP 800-53B). Text in square brackets is a parameter your organisation sets.
These are the artefacts auditors commonly ask for on this requirement, our guidance rather than text from the standard. Your assessor decides what is sufficient in your context, and asks for samples across the period when a report covers one.
system holds itEvidence a system already holds
- Records of integrity scans · Vulnerability scanner / patch tooling
- Automated tools supporting alerts and notifications for integrity discrepancies · SIEM / log platform
periodic reviewEvidence produced at each review
- Test of Software, firmware, and information integrity verification tools; mechanisms providing integrity discrepancy notifications · Document repository
governing documentDocuments that govern the control
- System and information integrity policy · Policy repository / GRC workspace
- System and information integrity procedures · Policy repository / GRC workspace
- Procedures addressing software, firmware, and information integrity · Policy repository / GRC workspace
- Personally identifiable information processing policy · Policy repository / GRC workspace
- System design documentation · Document repository
- System configuration settings and associated documentation · Policy repository / GRC workspace
- Integrity verification tools and associated documentation · Document repository
First move
Common gaps auditors find
- Integrity discrepancies are written to local logs with no automated notification to the defined personnel
- Automated integrity notifications are configured but routed to a decommissioned distribution list
Do this for your whole sheet
Paste the rows you run your controls from and get this mapping for every control at once, with the periodic-review ones flagged and a first move per row. No account for the first run.
Build my evidence sheetSI-7(1) Software, Firmware, and Information Integrity | Integrity Checks · SI-7(3) Software, Firmware, and Information Integrity | Centrally Managed Integrity Tools