PE-6 Monitoring Physical Access
Monitor physical access to facility; review access logs at least weekly (FedRAMP); coordinate review with IR.
Source: FedRAMP High (NIST SP 800-53 Rev 5 baseline), PE-6. The statement above is our statement of the clause, read from the published text and cited so you can check it against the official text, not the instrument verbatim. Open FedRAMP High (NIST SP 800-53 Rev 5 baseline) in the compliance library.
A FedRAMP baseline is a subset of NIST SP 800-53 Rev 5, enhancements included.
These are the artefacts auditors commonly ask for on this requirement, our guidance rather than text from the standard. Your assessor decides what is sufficient in your context, and asks for samples across the period when a report covers one.
system holds itEvidence a system already holds
- CCTV retention configuration and footage spot check evidence · Physical access / facilities
- Environmental monitoring readings for temperature, humidity, and water leak sensors · Physical access / facilities
periodic reviewEvidence produced at each review
- Weekly physical access log review records with anomalies escalated · Physical access / facilities
- Visitor sign in records with escort assignment · Physical access / facilities
- Fire suppression and UPS maintenance records · Backup / DR tooling
governing documentDocuments that govern the control
- SSP PE-6 statement describing physical access monitoring, weekly log review and coordination with incident response · Policy repository / GRC workspace
First move
Common gaps auditors find
- Environmental sensor alerts route to unmonitored mailboxes
- Server room doors propped open during cooling failures
- CCTV coverage gaps at loading docks and equipment delivery areas